VALTORC
Valtorc -- Valves, Actuators, Automation Products, Controls & Systems Integration
Valtorc Valves & Actuators
Performance Not Promises
1.800.317.7101
Home About Us Request For Quote Contact Us
Home
Valves
Actuators
Automation Packages
Letter From President
Get Quote
Click Here for Slideshow
VALTORC
1-866-VALTORC
770-423-7100
Fax 770-499-7483
PO Box 1928
3105 Carter Circle
Kennesaw GA 30144
email: controls9@aol.com

 

70 Years Experience In Automation Products, Controls & System Integration

Control Valves


Control Valves

  • Bronze Body
  • Two Way Single Seat
  • Stainless Trim
  • Size: 1/2" Reduced Port
  • Bronze Body
  • Two Way Single Seat
  • Stainless Trim
  • Size: 1/2" - 2"
  • Bronze Body
  • Two Way Single Seat
  • Bronze Trim
  • Size: 3/4" - 2"
  • Iron Body
  • Two Way Single Seat
  • Bronze Trim
  • Size: 2-1/2" - 6"
  • Bronze & Iron Body
  • Two Way Double Seat
  • Bronze & Stainless Trim
  • Size: 1" - 8"
  • Bronze & Iron Body
  • Three Way Mixing
  • Bronze Trim
  • Size: 1/2" - 6"

Industrial Control Valves


Heavy Industrial Globe


Light Industrial Globe


Compact Globe

  • Sizes 2-1/2" to 6"
  • Carbon Steel body
  • 316 Stainless trim
  • Class 150 & 300 flanged
    end connectors
  • ANSI Class 300 pressure
  • ANSI Class IV shutoff
  • Sizes 2-1/2" to 10"
  • Cast Iron body
  • 300 Stainless trim
  • Class 125 or 250 flanged
    end connectors
  • ANSI Class 250 pressure
  • ANSI Class III shutoff
  • Sizes 1/2" to 2"
  • Bronze, Steel, Stainless Steel body
  • 316 Stainless trim
  • Threaded Bronze & SS, 150/300
    flanged Steel & SS end connectors
  • ANSI 250 Bronze & ANSI 300
    Steel pressure
  • ANSI Class IV shutoff

Three-Way Globe

Cage-Guided Globe

Rotary Globe
  • Sizes 1/2" to 12"
  • Bronze, SS, Cast Iron, Steel body
  • 316 Stainless trim
  • NPT Threaded, Class 150 & 300
    Flanges, Class 125 & 250 Flanges
    end connectors
  • ANSI Class 250 & 300 pressure
  • ANSI Class III shutoff
  • Sizes 1" to 12"
  • Steel & SS body
  • 17-4 Stainless trim
  • Class 150 & 300 flanged
    end connectors
  • ANSI Class 600 pressure
  • ANSI Class II shutoff
  • Sizes 1" to 8"
  • Steel & SS body
  • 17-4 Stainless trim
  • Class 150/300/600 flangeless
    end connectors
  • ANSI Class 600 pressure
  • ANSI Class IV shutoff

Pneumatic Control Valves – Linear


TFE Angled Body


TFE Globe Body


Corrosion Proof Globe

  • Sizes 1/2" to 2"
  • TFE body with SST shell
  • 150# & 300# flanged, PN40
    end connectors
  • 275 psig at 0-55°F;
    150 psig at 180°F;
    50 psig at 280°F
  • Max Cv up to 50;
    smallest/full port
  • Sizes 1/2" to 2"
  • TFE body with SST shell
  • 150# & 300# flanged,
    PN40 end connectors
  • 275 psig at 0-55°F;
    150 psig at 180°F;
    50 psig at 280°F
  • Max Cv up to 50;
    smallest/full port
  • Sizes 1/2" to 1"
  • ANSI Class 600 for SST
  • NPT, SW and flangeless
    end connectors
  • 316L SST, Alloy 20,
    Monel, Ni-Mo-Cr body
  • Metal or TFE Seat
  • -50° to 450°F
  • Shutoff ANSI/FCI 70-2,
    Class IV or VI

Bellows Stem Seal

ANSI 300# Globe


BRZ Body

  • Primary metal bellows
    stem seal
  • Live-loaded secondary
    packing seal
  • 316L SST or HC-22
  • 200 psig max operating
    pressure
  • Sizes 3/4" to 3"
  • End connectors are
    integral or slip-on flanges
  • Up to 100 Cv; reduced
    port/full port
  • CI or CS body
  • Sizes 1/2" to 2" NPT
  • Up to 50 Cv; reduced
    port/full port
  • BRZ or CI body

Corrosion Proof Globe
 
  • Sizes 3/4" to 2"
  • ANSI Class 300
  • NPT, SW, separable
    flanged for Class 150, 300,
    PN40 end conn.
  • CS, 316 SST, Ni-Mo-Cr body
  • Metal or TFE Seat
  • -20° to +450°F
  • Shut off ANSI/FCI 70-2,
    Class IV or VI

Certifications

VALTORC
1-866-VALTORC I 770-423-7100 I Fax 770-499-7483
PO Box 1928 I 3105 Carter Circle I Kennesaw GA 30144

email: controls9@aol.com

Home About Us Request For Quote Contact Us

Site Map Download Catalog Contact Us © 2007 VALTORC, All Rights Reserved